vmError: Warning, the Safe Path is not accessible (does not exist or no permission). For safety reasons it is very important to create a folder in a path not accessible by an URL or unguessable name, create also a folder 'invoices' and 'keys' in it to store your sensitive data secure. Our suggested path is for your system '/home/muvigoco/vmfiles/'.
You can also use complex folder name as 'password' for example '/home/muvigoco/public_html/administrator/components/com_virtuemart/GFwP60ObCQBS/'. Use this link to the config

×

Warning

Key folder in safepath unaccessible

Print

Multi-Parameter Patient Monitor 8inch

multi-parameter monitor is an affordable compact patient monitor for monitoring of essential basic parameters of ECG, RESP, temperature, O2saturation and non-invasive blood pressure.

Description

Applications
MAS-70 multi-parameter monitor is an affordable compact patient monitor for monitoring of essential basic parameters of ECG, RESP, temperature, O2saturation and non-invasive blood pressure.

Features
1. Our Deluxe-70 multi-parameter monitor just weighs 1.3kg with battery. Lightweight and portable, it provides bedside monitoring and allows easy patient transport.
2. It comes with a 7inch color display which allows simultaneous display of up to 7 curves.
3. Accessories for adult, neonatal and pediatric patients are available.
4. The multi-parameter monitor provides visual and audible alarms with individual alarm setting.
5. Maximum 480 hours trend graphs enable nearly all parameters and trends to be listed.
6. Different mounting solutions are available, such as wall mounting, rolling stand mounting and bed assembly methods.
7. Network capacity with PC-1000A central station is optional.

Specifications of Deluxe-70 Multi-Parameter Monitor

ECG Heart rate display range 15bpm ~ 350bpm
Heart rate display accuracy ± 1% or ± 2bpm, whichever is greater
Sweeping speed 12.5mm/s, 25mm/s, 50mm/s
Sensitivity selection ×1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV
CMRR ≥ 89dB
RESP Measuring range 0rpm~120rpm
Accuracy ±5% or ±2 rpm
Alarm limits setting range 0rpm~120rpm
TEMP Measuring range 25.0℃ ~45.0℃
Measuring accuracy ±0.2℃
Responding time ≤150s
NIBP Measuring method Oscillometric Technique
Measuring range 0 mmHg~300mmHg
Accuracy Maximal mean difference ±5 mmHg
Maximal standard deviation 8 mmHg
Measurement range Adult SYS 40 ~ 255 mmHg
MAP 20 ~ 215 mmHg
DIA 10 ~ 195 mmHg
Pediatric patient SYS 40 ~ 200 mmHg
MAP 20 ~ 165 mmHg
DIA 10 ~ 150 mmHg
Neonate SYS 40 ~ 135 mmHg
MAP 20 ~ 110 mmHg
DIA 10 ~ 95 mmHg
SpO2 Measuring range 35%~100%
Low perfusion capability 0.4%~5%
Accuracy Not greater than 3% for SpO2 range from 70% to 100%
PR Measuring range 30bpm~240bpm
Measuring accuracy ±2bpm or ±2%, whichever is greater

 